Schneider Electric - 3 Pole, 480 VAC, 9 Continuous Amp, 2 hp at 200 Volt, 2 hp at 230 Volt, 5 hp at 460 Volt & 7-1/2 hp at 575 Volt hp, Enclosed IEC Combination Starter - CSA File No. LR23506 41 Class 3211 04, UL E154118 CCN NLDX CCN NLDX7


Item #: 56804842
Brand: Schneider Electric
Model #: LE2D096B62OT70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) starts are electrically controlled switches used to rapidly open (break) and close (make) a circuit. Similar to National Electrical Manufacturers' Association (NEMA) starters, IEC starters are much smaller and can provide quicker detection of overload conditions.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Three-phase refers to three individual lines (coils) that connect to and run voltage through the motor. Each line alternates in a sequence as they reach their voltage peak. They provide a more stable flow of voltage and more horsepower to the equipment.
Reversing starters are designed with three individual lines that connect to and run voltage through a motor. Each line alternates in a sequence as they reach their voltage peak. They are used to reverse the rotation of a motor.
Product Specifications
Continuous Amperage 9
Starter Type IEC
Enclosure Type Enclosed
Compatible Motor Phase Three Phase
Action Reversible
Voltage 480 VAC
Number of Poles 3
Horsepower (HP) 2 @ 200 V; 2 @ 230 V; 5 @ 460 V; 7-1/2 @ 575 V
Overall Height (mm) 499
Overall Height (Decimal Inch) 19.6300
Overall Width (Inch) 10
Overall Width (Decimal Inch) 10
Overall Width (mm) 254
Overall Depth (mm) 197
Overall Depth (Decimal Inch) 7-3/4
Standards Met CSA File No. LR23506 41 Class 3211 04; UL E154118 CCN NLDX CCN NLDX7

$1,333.31

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, NEMA Size 0-1, 16 to 24 Amp, 690 VAC, Thermal NEMA Overload Relay - Trip Class 20, For Use with LC1D18, LC1D25, LC1D32 and LC1D38


Item #: 69527372
Brand: Schneider Electric
Model #: LRD22L
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 0-1
For Use With LC1D18; LC1D25; LC1D32; LC1D38
Voltage 690 VAC
Maximum Overload (A) 24
Sensing Method Thermal
Minimum Overload (A) 16
Trip Class 20
Number of Poles 3
Overall Depth (mm) 76.10
Overall Depth (Inch) 3
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ABS; ATEX D 94/9/CE; ATEX INERIS; CSA; CSA C22.2 No. 14; EAC; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL; UL 508

$85.72

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 3 Pole, 600 VAC, 18 Continuous Amp, 5 hp, Enclosed NEMA Combination Starter - NEMA 1, RoHS Compliant, 30 Amp Short Circuit Protection


Item #: 69526119
Brand: Square D
Model #: 8538SBG13V02S
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Three-phase refers to three individual lines (coils) that connect to and run voltage through the motor. Each line alternates in a sequence as they reach their voltage peak. They provide a more stable flow of voltage and more horsepower to the equipment.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Continuous Amperage 18
Starter Type NEMA
Enclosure Type Enclosed
Compatible Motor Phase Three Phase
Action NonReversible
Voltage 600 VAC
Number of Poles 3
Horsepower (HP) 5
Short Circuit Protection (A) 30
Standards Met NEMA 1; RoHS Compliant

$1,384.21

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1.2 to 1.8 Amp, 250 VDC, 690 Volt and 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1K, LC7K, LP1K and LP4K


Item #: 64681794
Brand: Schneider Electric
Model #: LR2K0307
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1K; LC7K; LP1K; LP4K
Voltage 250 VDC; 690 V; 690 VAC
Maximum Overload (A) 1.80
Sensing Method Thermal
Minimum Overload (A) 1.20
Trip Class 10A
Overall Height (mm) 58
Overall Width (mm) 65
Standards Met BS 4941; IEC 60947; NF C 63-650; VDE 0660

$88.26

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - Starter Definite Purpose Heater Pack - For Use with B Series Overload Relay IEC G-K, B Series Overload Relay NEMA 1-2, C Series Overload Relay IEC A-F, C Series Overload Relay NEMA 00-0


Item #: 02353480
Brand: Eaton Cutler-Hammer
Model #: H2001B-3
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Definite Purpose Heater Pack
For Use With B Series Overload Relay IEC Sizes G-K; B Series Overload Relay NEMA Sizes 1-2; C Series Overload Relay IEC Sizes A-F; C Series Overload Relay NEMA Sizes 00-0
Includes (3) Heaters

$181.94

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 24 to 32 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10, For Use with 25-32A Contactors


Item #: 08805376
Brand: Eaton Cutler-Hammer
Model #: XTOB032CC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With 25-32A Contactors
Voltage 690 VAC
Maximum Overload (A) 32
Sensing Method Thermal
Minimum Overload (A) 24
Trip Class 10
Overall Height (Decimal Inch) 1.8900
Overall Height (mm) 48
Overall Depth (mm) 83
Overall Depth (Decimal Inch) 3.2700
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ATEX Compliant; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed

$199.85

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 250 VAC, IEC Overload Relay


Item #: 56806219
Brand: Schneider Electric
Model #: LT3SE00F
Exact Tooling IR#: 04

Product Specifications

250 VAC, IEC Overload Relay -
Starter Type IEC
Voltage 250 VAC
Overall Height (mm) 100
Overall Width (mm) 100
Standards Met IEC 60034-11; VDE 0660

$264.89

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 60 to 100 Amp, 690 Volt, Thermal IEC Overload Relay - Trip Class 10 and 20, For Use with LC1D115, LC1D150 and NSX Circuit Breaker


Item #: 56805443
Brand: Schneider Electric
Model #: LR9D67
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D115; LC1D150; NSX Circuit Breaker
Voltage 690 V
Maximum Overload (A) 100
Sensing Method Thermal
Minimum Overload (A) 60
Trip Class 10; 20
Overall Width (mm) 132
Standards Met EN/IEC 60947-4-1; IEC 255-17; IEC 255-8; VDE 0660

$445.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 to 13 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D40A and LC1D65A


Item #: 56805476
Brand: Schneider Electric
Model #: LR3D313
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D40A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 13
Sensing Method Thermal
Minimum Overload (A) 9
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$160.15

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 30 to 40 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1D80 and LC1D95


Item #: 69648186
Brand: Schneider Electric
Model #: LR3D3555
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D80; LC1D95
Voltage 690 VAC
Maximum Overload (A) 40
Sensing Method Thermal
Minimum Overload (A) 30
Trip Class 20
Overall Width (mm) 121
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$149.68

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 1.6 to 2.4 Amp, 690 VAC, IEC Overload Relay - Trip Class 10


Item #: 08805525
Brand: Eaton Cutler-Hammer
Model #: XTOM2P4AC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
Voltage 690 VAC
Maximum Overload (A) 2.40
Minimum Overload (A) 1.60
Trip Class 10
Standards Met ATEX Compliant; CCC; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed; VDE 0660

$92.03

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 120 VAC, 9 Continuous Amp, Enclosed IEC Combination Starter - NEMA 12/3R


Item #: 56805187
Brand: Schneider Electric
Model #: LE1D096B72OG70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) starts are electrically controlled switches used to rapidly open (break) and close (make) a circuit. Similar to National Electrical Manufacturers' Association (NEMA) starters, IEC starters are much smaller and can provide quicker detection of overload conditions.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Continuous Amperage 9
Starter Type IEC
Enclosure Type Enclosed
Action NonReversible
Voltage 120 VAC
Number of Poles 3
Standards Met NEMA 12/3R

$1,032.43

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 2 Poles, 30 Amp, NEMA, Enclosed Key Manual Motor Starter - 1 hp at 90 VDC, 1-1/2 hp at 230 VDC, 2 hp at 115 VAC, 2 hp at 115 VDC, 2 hp at 230 VAC, 3 hp at 460 VAC & 3 hp at 575 VAC, CE, CSA, NEMA 1 & UL Listed


Item #: 56819279
Brand: Square D
Model #: 2510KG3B
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Key switches are operated with a removable key. It is designed to ensure the proper user can operate the starter
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Product Specifications
Starter Type NEMA
Amperage 30
Operator Type Key
Enclosure Type Enclosed
Horsepower (HP) 1 @ 90 VDC; 1-1/2 @ 230 VDC; 2 @ 115 VAC; 2 @ 115 VDC; 2 @ 230 VAC; 3 @ 460 VAC; 3 @ 575 VAC
Number of Poles 2
Standards Met CE; CSA; NEMA 1; UL Listed

$257.63

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 2.4 to 4 Amp, 690 VAC, IEC Overload Relay - Trip Class 10


Item #: 08805475
Brand: Eaton Cutler-Hammer
Model #: XTOM004AC1
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
Voltage 690 VAC
Maximum Overload (A) 4
Minimum Overload (A) 2.40
Trip Class 10
Standards Met ATEX Compliant; CCC; CE Marked; CSA Certified; EN/IEC 60947; RoHS Compliant; UL Listed; VDE 0660

$92.03

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, NEMA Size 00-1, 7 to 10 Amp, 690 VAC, Thermal NEMA Overload Relay - Trip Class 20, For Use with LC1D09, LC1D12, LC1D18, LC1D25, LC1D32 and LC1D38


Item #: 69527331
Brand: Schneider Electric
Model #: LRD14L
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 00-1
For Use With LC1D09; LC1D12; LC1D18; LC1D25; LC1D32; LC1D38
Voltage 690 VAC
Maximum Overload (A) 10
Sensing Method Thermal
Minimum Overload (A) 7
Trip Class 20
Number of Poles 3
Overall Depth (mm) 76.10
Overall Depth (Inch) 3
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ABS; ATEX D 94/9/CE; ATEX INERIS; CSA; CSA C22.2 No. 14; EAC; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL; UL 508

$83.37

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 12 Amp, 208 Coil VAC, 50/60 Hz, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 1/2 at 115 Volt, 2 at 230 Volt, 3 Phase Hp: 10 at 575 Volt, 3 at 200 Volt, 3 at 230 Volt, 7.5 at 460 Volt


Item #: 56805112
Brand: Schneider Electric
Model #: LE1D123A72OL70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) motor starters are contactors with overload relays and used for turning an electrical motor on/off, reversing motion and providing protection for overloads in electrical equipment. They are similar to National Electrical Manufacturers' Association (NEMA) motor starters, but are smaller in size and quicker to find detection of overload conditions.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type IEC
Amperage 12
Coil Voltage 208 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 10 @ 575 V; 3 @ 200 V; 3 @ 230 V; 7.5 @ 460 V
Horsepower at 1 Phase 1/2 @ 115 V; 2 @ 230 V
Enclosure Type Enclosed
Number of Poles 3
Frequency Rating (Hz) 50/60
Overall Height (mm) 255
Overall Height (Decimal Inch) 10.0400
Overall Width (mm) 172
Overall Width (Decimal Inch) 6.7700
Overall Depth (mm) 158
Overall Depth (Decimal Inch) 6-1/4
Standards Met CSA File No. LR23506 41 Class 3211 04; UL E154118 CCN NLDX CCN NLDX7

$378.28

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 9 Amp, 480 Coil VAC, 50/60 Hz, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 1 at 230 Volt, 1/3 at 115 Volt, 3 Phase Hp: 2 at 200 Volt, 2 at 230 Volt, 5 at 460 Volt, 7.5 at 575 Volt


Item #: 56805195
Brand: Schneider Electric
Model #: LE1D093A72OT70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) motor starters are contactors with overload relays and used for turning an electrical motor on/off, reversing motion and providing protection for overloads in electrical equipment. They are similar to National Electrical Manufacturers' Association (NEMA) motor starters, but are smaller in size and quicker to find detection of overload conditions.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type IEC
Amperage 9
Coil Voltage 480 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 2 @ 200 V; 2 @ 230 V; 5 @ 460 V; 7.5 @ 575 V
Horsepower at 1 Phase 1 @ 230 V; 1/3 @ 115 V
Enclosure Type Enclosed
Number of Poles 3
Frequency Rating (Hz) 50/60
Overall Height (mm) 255
Overall Height (Decimal Inch) 10.0400
Overall Width (mm) 172
Overall Width (Decimal Inch) 6.7700
Overall Depth (mm) 158
Overall Depth (Decimal Inch) 6-1/4
Standards Met CSA File No. LR23506 41 Class 3211 04; UL E154118 CCN NLDX CCN NLDX7

$328.32

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 Amp, 120 Coil VAC, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 0.3 at 120 VAC, 1 at 240 VAC, 3 Phase Hp: 2 at 208 VAC, 2 at 230 VAC, 5 at 460 VAC, 7.5 at 575 VAC


Item #: 69527612
Brand: Schneider Electric
Model #: LE1D093A72OG70
Exact Tooling IR#: 04

Features and Benefits

Enclosed full voltage starters connect the incoming power directly to the motor and are used in applications where the motor runs in only one direction and speed.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Enclosed Full Voltage Starter
Amperage 9
Coil Voltage 120 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 2 @ 208 VAC; 2 @ 230 VAC; 5 @ 460 VAC; 7.5 @ 575 VAC
Horsepower at 1 Phase 0.3 @ 120 VAC; 1 @ 240 VAC
Enclosure Type Enclosed
Standards Met CSA; IEC; NEMA 12; UL

$306.93

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 63 to 80 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D80 and LC1D95


Item #: 69527604
Brand: Schneider Electric
Model #: LRD3363
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D80; LC1D95
Voltage 690 VAC
Maximum Overload (A) 80
Sensing Method Thermal
Minimum Overload (A) 63
Trip Class 10A
Overall Height (mm) 123
Overall Width (mm) 121
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$191.51

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 65 Amp, 120 Coil VAC, 50/60 Hz, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 10 at 230 Volt, 5 at 115 Volt, 3 Phase Hp: 20 at 200 Volt, 20 at 230 Volt, 40 at 460 Volt, 50 at 575 Volt


Item #: 56829393
Brand: Schneider Electric
Model #: LE1D653A72OG70
Exact Tooling IR#: 04

Features and Benefits

International Electrotechnical Commission (IEC) motor starters are contactors with overload relays and used for turning an electrical motor on/off, reversing motion and providing protection for overloads in electrical equipment. They are similar to National Electrical Manufacturers' Association (NEMA) motor starters, but are smaller in size and quicker to find detection of overload conditions.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type IEC
Amperage 65
Coil Voltage 120 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 20 @ 200 V; 20 @ 230 V; 40 @ 460 V; 50 @ 575 V
Horsepower at 1 Phase 10 @ 230 V; 5 @ 115 V
Enclosure Type Enclosed
Number of Poles 3
Frequency Rating (Hz) 50/60
Overall Height (mm) 275
Overall Height (Decimal Inch) 10.8300
Overall Width (mm) 220
Overall Width (Decimal Inch) 8.6600
Overall Depth (mm) 183
Overall Depth (Decimal Inch) 7.2100
Standards Met CSA File No. LR23506 41 Class 3211 04; UL E154118 CCN NLDX CCN NLDX7